The RDS-40WE is a Digital Handheld Dose Rate Meter designed for use by personnel who may be exposed to gamma and/or X-ray radiation in their work. RDS-40WE provides either sequential or fi xed dose rate alarming system (values are programmable by the CSW confi guration software via IrDA link) and the possibility to store dose rate events into the histogram memory of the meter.
The use of the RDS-CSW software (Mirion product # 1233-246) is required for downloading the data into a PC via IrDA port.
RDS-40WE is microprocessor controlled. The user interface consists of one push button and an easy-to-use menu structure that displays information in the LCD of the meter. The six digit display shows the dose rate and various messages. Diff erent alarm situations are indicated by a combination of audio-visual eff ects in the LCD and a buzzer (dose rate, dose , low battery, defect, dose rate overfl ow).

Features
• Wide Energy range 16.3 keV...3 MeV
• measurement according to H*(10)
• dose measurement indication
• high battery life time (>1 year)
• compliant to IEC 60846*
• dose rate follow-up by audible signal with frequency proportional to dose rate
• visual and audible alarm: user settable for dose and dose rate over the whole measurement range
• histogram capability of up to 480 dose rate values with user settable logging interval
• backlight display with six large digits
• display in either μSv/h or in mrem/h
• built-in self diagnostics
• enclosure class IP67
* see Radiological Characteristics
Radiological Characteristics
• radiation detected: gamma and x-rays, 16.3 keV (}30o) 24keV... 3 MeV}45o
• detector: one energy-compensated GM tube. Energy response according to ambient
dose equivalent H*(10)
• measurement range: eff ective dose rate 0. 1 μSv/h – 50 mSv/h or 10 μrem/h – 5 rem/h,
dose 0.1 μSv – 1 Sv or 10 μrem – 100 rem
• alarm levels: adjustable alarm levels for dose rate and accumulated dose
• calibration accuracy: } 5 % of the reading in 137Cs exposure, at 3 mSv/h (300 mrem), +20°C (68°F)
• dose rate linearity: }18% in the whole measurement range
• response to radiation energy -29 % to +67 % over the range of 16.3 keV to 3 MeV
Functional Characteristics
• visual and audible alarm: user settable for dose and dose rate
• histogram capability of up to 480 points with user settable logging interval 10s ... 14 400s
• backlit display with six large digits
• built-in self diagnostics
• IrDA link to PC
Electrical Characteristics
• power supply: 2 alkaline batteries IEC LR6/AA size (recommended)
• battery life time: at least 1000 hours at normal background with alkaline cells
• battery alarm: two-step alarm for low battery voltage
Mechanical Characteristics
• rugged plastic case
• resistant against RF interferences
• enclosure class: IP67
• dimensions: 78 x 126 x 57 mm
• weight: 294 g without batteries, 342 g with batteries
Environmental Characteristics
Temperature range:
•  -25...+55°C operational (-13°F to 131°F)
•  -40...+70°C storage (-40... 158°F)
Accessories
• CSW confi guration software
• wrist strap
• neck strap