Tampilkan postingan dengan label Pendose. Tampilkan semua postingan
Tampilkan postingan dengan label Pendose. Tampilkan semua postingan

PENDOS DIGITAL PDM-112 MYDOSE

PENDOS DIGITAL PDM-112 MYDOSE

Product Information

HARGA

Rp       14,500,000.00
= = = = = = = = = = = = = = = = = = = = = =
(UPDATE 4 FEBRUARI 2013)
= = = = = = = = = = = = = = = = = = = = = =
> Kondisi barang indent 12 minggu.
> Langsung kalibrasi.
> Harga sudah termasuk kalibrasi pertama kali dan pengiriman ke tempat tujuan.
> Jika menghendaki transaksi an. Perusahaan, maka harga masih belum termasuk ppn 10%. (Jika ingin transaksi resmi bukan pribadi).


The PDM are excellent electronic pocket dosimeters that use a semiconductor detector which is sensitive to gamma and x-rays.
Both models are battery operated and do not require a charger, separate reader or developing.
Radiation Detected: gamma & x-ray 20 keV & above
Measuring Range: 1-9999 mSv
Battery Life: 2 weeks
Size: 1.2 " w x 5.9 " l x .49 " d
Weight: 1.8

FEATURES
• High sensitivity
• Easy-to-handle, compact and lightweight
• Silicon semiconductor
• Easy-to-read digital display
• Data-holding function
• Lithium battery powered Low battery/overflow indication
• No reader required
• Temperature range: 0 to +45o C

SPECIFICATIONS FOR PDM-112
• Radiation Detected: Gamma (X-ray)
• Energy Threshold: 40 keV
• Detector: Silicon semiconductor
• Measurement Range: 1 to 9999 uSv
• Energy Dependance: Within + 30% from 50 keV to 3 MeV
• Accuracy: Within + 10% from 10 to 9999 uSv (calibrated by
• 137Cs using a slab phantom)
• Linearity: Within + 10% up to 0.1 Sv/h, within + 20% from 0.1 to 0.3 Sv/h
• Display: 4-digit LCD
• Other: Display test function, overflow indication, low battery indication, data storage function(*)
• (*) The measure value is stored unless the battery is removed or the
• power switch is pressed for ten seconds when turning on the instrument.
• Power Supply: One lithium battery, CR2450 (coin size)
• Battery Life: Approximately one month of continuous use
• Environmental Requirements: Temperature: 0 to +45 degrees C

DMC 3000 Electronic Dosimeter


DMC 3000 Electronic Dosimeter

Product Information

HARGA
Rp         14,500,000.00
= = = = = = = = = = = = = = = = = = = = = =
(UPDATE 4 FEBRUARI 2013)
= = = = = = = = = = = = = = = = = = = = = =

> Kondisi barang Ready Stock.
> Langsung kalibrasi.
> Harga sudah termasuk kalibrasi pertama kali dan pengiriman ke tempat tujuan.
> Jika menghendaki transaksian. Perusahaan, maka harga masih belum termasuk ppn 10%. (Jika ingin transaksi resmi bukan pribadi).

Covering a wide range of X-Ray and Gamma radiation detection, the DMC 3000 Electronic Dosimeter represents over 25 years of real-world electronic dosimetry experience, continually refined through customer feedback.
The unique, high contrast and backlit LCD display provides a clear indication of wearer's dose and ambient dose rate for deep dose equivalent. More importantly, multiple methods (audible, visual, and tactile) are utilized to alert the wearer of alarm conditions.
Features:
• Loud Alarm, > 85 dB Peak
• Vibrating alarm
• Highly Visible Backlit Display
• Optional Telemetry
• Factory Upgradeable Firmware
• Simple 2-Button Navigation
• Extended Dose Rate Alarms
• Dual UltraBright LED Alarm
• Superior X-Ray and Gamma Energy Response
• Meets or Exceeds Applicable IEC and ANSI Standards
• Designed for Ruggedness and Durability
PHYSICAL CHARACTERISTICS
Compliant with IEC 61526Ed. 3, ANSI 42.20(*) (*) isotropy 241Am and 137Cs with ± 75° angle
Measurement and display:
X and gamma energy range: 15 keV to 7 MeV
Energy response better than ± 20% (typically ± 10%) from 16 keV to 7 MeV
Accuracy Hp(10): ≤ ± 10%* (137Cs, ~ 24 mSv/h); ≤ ± 15%*, (241Am, ~ 23 mSv/h); ≤ ± 19%** X-ray 16keV (*including ± 5% extended uncertainty k=2) ; (** including ± 9% extended uncertainty k=2)
Display units: mSv, μSv, or mrem
Display dose: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
Display rate: 10 μSv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 μSv/h to 10 Sv/h (0.1 mrem/h to 1000 rem/h) extended option.
Measurement range: 1 μSv to 10 Sv (0.1 mrem to 1000 rem) 0.1 μSv/h to 20 Sv/h (0.01 mrem/h to 2000 rem/h),
Saturation indication above 10 Sv (1000 rem) or 10 Sv/h (1000 rem/h)
Dose Rate Linearity:
< ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 keV)
< ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X-rays 20 ms width, 1, 10 & 20 pps)
ELECTRICAL CHARACTERISTICS
Standard AAA (LR03) 1.5 V Alkaline battery
9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms)*
2500 h battery life in continuous run, without excessive alarm*
*0.2% of the time in alarm
MECHANICAL CHARACTERISTICS
Rugged, high impact polycarbonate-ABS case
Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip
Weight with alkaline battery and clip: < 88 g (3.1 oz)
Worn by a replaceable clips (2 different style back clips or one a front-facing clip for DMC worn inside the pocket)
ENVIRONMENTAL CHARACTERISTICS
Temperature range: -10°C to 50°C (14°F to 122°F): deviation in response less than ± 5%
Relative humidity: < 90% at 42°C (108°F)
Storage: -20°C to 71°C (-4°F to 160°F)
Shock, vibration and drop resistant (1.5 meter on concrete)
Waterproof IP67: 1m (39 in) during 1 hour
EMC: complies and exceeds standards by a large margin ( compliant, certificate number: 153720)
MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 kHz to 5 GHz
MIL STD 461F RS101 (magnetic field 30 Hz - 100 kHz)
Factory calibration approved under ISO/IEC 17025, COFRAC accreditation Nber 2-1663
Histogram Features
Dose increments with a 1 μSv (0.1 mrem) resolution saved on non volatile memory (EEPROM) in configurable steps (10 s, 60 s, 10 min, 1 hour, 24 hours)
Dose rate saved at each dose increment when using enhanced communication protocol
Event log (alarms, faults, changes) saved during the selected time periods
Stores data for several consecutive workers entries and exits (more than 1000 steps)
Display Features
Large LCD display with high quality white backlighting
8 alpha-numeric digit display for full name display (scrolling) and fix dose/rate display format
3 top LEDs for Alarming (Red), gamma counting (Green) and Hp(0.07) or Neutron counting (Blue)
2 push buttons for an easy customized data and parameters display
Alarm Features and communication
Alarming speaker with level of 85 dB (A) typical (> 90 dB (C) peak) at 30 cm (11.8 in), frequency < 4800 Hz
Vibrating alarm
High efficiency red flash LED on front
3 Top LEDs and display indicators
Dose/rate alarms, adjustable over the display range
Dose/rate warnings, adjustable over the display range and acknowledgeable
Remaining time before alarm and run time alarms
Hands-free communication, frequency: 125 kHz
Backward compatibility with existing readers (LDM 2000, LDM 220/210)
Range of communication with LDM 220: 10 cm (3.9 in)
Enhanced protocol to support additional features with the new readers (LDM 320D, LDM 320W, LDM 2000 (*))
* requires reader firmware upgrade

Pen Dosimeters Analog (Pendos)

Pen Dosimeters Analog (Pendos)

Product Information
HARGA
Rp         3,750,000.00
= = = = = = = = = = = = = = = = = = = = = =
(
UPDATE 4 FEBRUARI 2013)
= = = = = = = = = = = = = = = = = = = = = = 
> Kondisi barang Ready Stock.
> Langsung kalibrasi.
> Harga sudah termasuk kalibrasi pertama kali dan pengiriman ke tempat tujuan.
> Jika menghendaki transaksi an. Perusahaan, maka harga masih belum termasuk ppn 10%. (Jika ingin transaksi resmi bukan pribadi).
 


The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose (quantity of gamma and x-ray exposure). PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.
Exposure Range (gamma and x-rays)
PEN200mR Scale increments of 10mR
PEN500mR Scale increments of 20mR
PEN2R increments of 100 mR
PEN5R increments of 200mR
PEN20R increments of 1R
PEN2mSv increments of .1mSv
PEN5mSv increments of .2mSv
National Stock Numbers Available

Energy Dependence
±10% maximum change in sensitivity for x and gamma ray energies from 16 keV to 8 MeV.
Electrical Leakage
In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50°C. At 20°C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R the leakage is less than 5% of full scale in 48 hours at 20°C. Thereafter, the leakage will decrease to original values.
Charging Voltage
Dosimeters are capable of being charged to “zero” with 140 to 195 volts.
Operational Characteristics
A maximum change in sensitivity of ±10% may occur under any probable combination of the following:
A) Temperature range below -20°C (-4°F) or above +50°C (122°F)
B) Greater than 50,000 foot altitude for one month
C) Relative humidity greater than 95% Highly resistant to shock and vibration.
Accuracy
±10% of true dose for Cs137 or Co60 gamma.
Rate Response
Dosimeters are dose rate independent.
Enclosure Material
Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic with metal clip.
Weight
Approx. 19 grams (0.7 oz.)
Size
PEN- 200, 500, 2mSv, 5mSv Length: 11 cm (4.5 inches) Diameter: 1.5 cm (0.6 inches)
PEN- 2, 5, 20 Length: 11.5 cm (4.5 inches) Diameter: 1.5 cm (0.6 inches)
Options
Protective sapphire lens
Limited Warranty
2 year limited warranty.

PENDOSE DIGITAL RAD 60

PENDOSE DIGITAL RAD 60 

Product Information

HARGA

Rp       13,500,000.00
= = = = = = = = = = = = = = = = = = = = = =
(UPDATE 4 FEBRUARI 2013)
= = = = = = = = = = = = = = = = = = = = = =
 
> Kondisi barang indent 12 minggu.
> Langsung kalibrasi.
> Harga sudah termasuk kalibrasi pertama kali dan pengiriman ke tempat tujuan.
> Jika menghendaki transaksi an. Perusahaan, maka harga masih belum termasuk ppn 10%. (Jika ingin transaksi resmi bukan pribadi).

Detail Specifications

The RADOS RAD-60 Personal Alarm Dosimeter is a precise and reliable instrument for ensuring the personal safety of the user. Ideally, the RAD-60 is used in everyday radiation monitoring, in stand-alone conditions. If your needs grow for a more sophisticated system, the RAD-60 can also be integrated into an Access Control System. The RAD-60 can be switched into System Mode, for the purpose of tracking Personnel Dose records and compliance reports.

Detector
Energy compensated Si-Diode

Button Functions
• change display (dose/dose rate)
• switch ON/OFF
• chirp ON/OFF
• reset integrated dose
• change alarm thresholds
• activate battery test

Measurement Range
Dose: 1 uSv - 9.99 Sv or 0.1 mrem - 999 rem

Energy Response
Hp(10), 60 keV - 3 MeV, better than + or - 25%,
up to 6 MeV, better than + or - 35%

Dose Rate
5 uSv/h - 3 Sv/h or 0.5 mrem/h - 300 rem/h

Dose Rate Linearity
Better than + or - 15% up to 3 Sv/h (300 rem/h)

Calibration
Better than + or -5% (Cs-137, 662 keV at 2 mSv/h), Hp(10)

Audible Alarms
Seven separate alarms, sound level typically better than 85 dBA at 30 cm
• integrated dose
• dose rate
• dose overflow
• dose rate overflow at 3 Sv/h or 300 rem/h
• low battery 1 and 2
• defect

Alarm Thresholds
Six preset values each for integrated dose and dose rate-push button selection

Connectors
Infrared communication via bottom of the dosimeter

Power Requirements
One triple A alkaline cell, typical life is 1800 hours in background

Temperature Range
-20 - + 50° C operational, humidity up to 90% RH, non-condensed
-20 - + 70° C storing

Weight
80 g (including battery)

Size
78 x 67 x 22 mm