The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose (quantity of gamma and x-ray exposure). PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.
Exposure Range
(gamma and x-rays)
PEN200mR Scale
increments of 10mR
PEN500mR Scale
increments of 20mR
PEN2R increments of
100 mR
PEN5R increments of
200mR
PEN20R increments of
1R
PEN2mSv increments of
.1mSv
PEN5mSv increments of
.2mSv
National Stock Numbers
Available
Energy
Dependence
±10% maximum change in
sensitivity for x and gamma ray energies from 16 keV to 8 MeV.
Electrical
Leakage
In the absence of
radiation, the dosimeters leakage or self discharge is less than 0.5% of full
scale in 24 hours at 50°C. At 20°C dosimeters will read background radiation.
After gross over exposure totaling up to 2000 R the leakage is less than 5% of
full scale in 48 hours at 20°C. Thereafter, the leakage will decrease to
original values.
Charging
Voltage
Dosimeters are capable
of being charged to “zero” with 140 to 195 volts.
Operational
Characteristics
A maximum change in
sensitivity of ±10% may occur under any probable combination of the following:
A) Temperature range
below -20°C (-4°F) or above +50°C (122°F)
B) Greater than 50,000
foot altitude for one month
C) Relative humidity
greater than 95% Highly resistant to shock and vibration.
Accuracy
±10% of true dose for
Cs137 or Co60 gamma.
Rate Response
Dosimeters are dose
rate independent.
Enclosure
Material
Barrel - carbon
fiber-filled, high-strength, electrically-conducting plastic with metal clip.
Weight
Approx. 19 grams (0.7
oz.)
Size
PEN- 200, 500, 2mSv,
5mSv Length: 11 cm (4.5 inches) Diameter: 1.5 cm (0.6 inches)
PEN- 2, 5, 20 Length:
11.5 cm (4.5 inches) Diameter: 1.5 cm (0.6 inches)
Options
Protective sapphire
lens
Limited
Warranty
2 year limited
warranty.