RDS-80A Contamination Survey Meter

RDS-80

Product Information

HARGA

nego
= = = = = = = = = = = = = = = = = = = = = =
(UPDATE 4 FEBRUARI 2013)
= = = = = = = = = = = = = = = = = = = = = =

> Kondisi barang Ready Stock.
> Langsung kalibrasi.
> Harga sudah termasuk kalibrasi pertama kali dan pengiriman ke tempat tujuan.
> Jika menghendaki transaksi an. Perusahaan, maka harga masih belum termasuk ppn 10%. (Jika ingin transaksi resmi bukan pribadi).

Description

The RDS-80 Surface Contamination Meter is a versatile contamination detector designed for a wide range of applications in radiation protection in nuclear industry and in rescue operations. It is suitable for personnel who need to locate and detect contaminated surfaces or objects during their work.

Features


• wide measurement range: up to 100 000 CPM or 1, 000 000 DPM
• standard surface contamination measurements in CPM or DPM
• contamination measurements with histogram function
• visual and audible alarms
• handy and easy to use design
• software for parameter setting, hitogram readings and nuclide calibration

Specification :

Radiological Characteristics :
• radiation detected: alpha > 2 MeV, beta > 100 keV, gamma and x-rays from 5 keV to 1.3 MeV
• detector: end window GM tube, 1, 5-2 cm2; MICA window Ø 4.4 cm ( 1.74” )
• measurement range: surface contamination 1 to 100 000 cps or 0.01 to 100 000 Bq/ cm2
• alarm levels: freely adjustable alarm levels for contamination level
• cps linearity: ± 15% ± 1 digit over the range. The Bq/ cm2 display is calculated from cps values by multiplying with Isotope coefficient

Functional Characteristics :
• display in either cps or Bq/ cm2
• surface activity ( Bq/ cm2) display configurable for different nuclides
• cps follow-up by audible signal with frequency proportional to activity
• visual and audible alarm: user settable for surface activity
• histogram capability of up to 480 points with user settable logging interval
• backlit display with six large digits
• built-in self diagnostics
• gamma background reduction for Bq/ cm2 measurements
• Built-in infra-red port ( IrDA)

Electrical Characteristics:
• power supply: 2 alkaline batteries IEC LR6/ AA size ( recommended)
• battery life time: at least 2000 hours at normal background with alkaline cells
• ( more than 1 year under normal operation)
• battery alarm: two-step alarm for low battery voltage
• electromagnetic compatibility: CE compliant

Mechanical Characteristics :
• rugged plastic case
• dimensions: 78 x 126 x 57 mm
• weight: 280 g without batteries, 330 g with batteries

Environmental Characteristics :
Temperature range:
• -25...+ 55° C operational ( -13... 131° F)
• -40...+ 70° C storage ( -40... 158° F)
• protection level IP67 ( temporary immersion / floating device